Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The manual was complete and extremely helpful in both diagnosing the problem I was having as well as fixing it. Excellent quality. I will getting additional manuals in the future.
 ;
Exactly the JVC service manual and schematics that I was looking for - delivered just hours after order. Will do business again!
 ;
This is a fantastic site, ad I have been a returning satisfied cusumer!
Thanx for a great sevice!
 ;
Je suis audiophile belge, électronicien et créateur d'enceintes acoustiques.
J'ai apprécié la qualité des documents fournis. Ils sont très lisibles, ils peuvent être agrandis sans problème et ils sont complets. Pour moi, c'est parfait. Pour cette qualité, je suis d'accord de payer. Et le système de paiement et d'envoi est simple. Merci, continuez comme cela.
Frédéric
 ;
The cover page was a little scary, very dark but readable. The remainder of the document was better copy and easily readable. Why would I give 5 Stars? (1) PRICE, (2) AUTHENTICITY, It was the real deal, filled with service information, including the specific information I required. (3) PRIVACY, I didn't start to get slammed with spam. (4) EASY TRANSACTION. Painless. (5) COMPLETE, I have found several manuals here, that I could find nowhere else. (6) I will be a repeat customer!
SPIN TROUBLE
Check the S.PRESSURE SWITCH ASSEMBLY or HOSE (Pressure). If the problem is on the S.PRESSURE SWITCH ASSEMBLY or the HOSE, replace the S.PRESSURE SWITCH ASSEMBLY or the HOSE.
Check on the spinning, is the frequency of the water level 248 or more. The frequency can be
Rinse Spin
checked by pressing the Rinse and Spin buttons at the same time on the program.
NO
YES
When pressing Rinse, Spin and POWER buttons at the same time after power off, press the Start/Pause YES
Rinse Spin
Normal
button 2 times, is the drum spinning at low speed?
NO
(2) (1)
Is it disconnected, or disassembled? [Red:3pin (1), NA:4pin (2)]
YES
Correct the connector.
NO
Check the motor connector, Is the resistance of the terminal same as the figure?
NO
MOTOR TERMINAL (1)
(1)
Replace the STATOR ASSEMBLY (4417FA1994E)
Resistance of terminal: About 5 10
YES
Replace the MAIN PWB ASSEMBLY